Radiation Monitoring

Ludlum 14C Survey Meter with Pancake GM Probe

The Model 14C Survey Meter meets the essential monitoring and surveying
needs of most nuclear medicine facilities. The exposure filter flattens the
response for energies between 33keV to 1.2MeV. For background readings, the
unit built‐in GM detector handles counts up to 2R/hr. For beta emitters, the
pancake probe has approximately twice the counting efficiency as an endwindow
detector. For high‐range gamma detection, the internal detector with
the ×1000 multiplier range is used.
Satisfies NRC requirements for nuclear medicine departments
• Monitoring alpha, beta and gamma
• 0‐2 R/hr range
• External pancake GM probe with exposure filter (39” cable included)
• Internal energy compensated GM detector
• Five counting scales (×0.1, ×1, ×10, ×100, ×1000)

Ludlum 14C Survey Meter with Pancake GM Probe

The Ranger / Radiation Survey Meter - a ß y

The Ranger / Radiation Survey Meter - a ß y

The Ranger offers maximum performance in a lightweight, rugged solution for surveying
at the facility or in the field. The Ranger has been designed for industrial environments,
but it still has all of the features you’ve come to love in the lab. The Ranger is a small,
handheld, digital instrument which offers excellent sensitivity to low levels of alpha,
beta, gamma, and x‐rays.

Detector
Internal Halogen‐quenched, uncompensated GM tube with thin mica window, 1.4‐2.0
mg/cm2 areal density. Effective diameter of window is 45 mm (1.77 in.).

Operating Range
mR/hr ‐ .001 (1μR) to 100
CPM ‐ 0 to 350,000
μSv/hr ‐ .01 to 1000
CPS ‐ 0 to 5000
Total Counts‐ 1 to 9,999,000 counts

Ludlum Contamination Monitor Model 26

The new cable‐less Ludlum M26 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard GM pancake probe, loud audio “click” output and large auto‐ranging LCD display with automatic back lighting into one convenient package, making it easier than ever to detect contamination.
• Range 1cpm to 99.9 kcpm
• Integrated, Lightweight Design Simplifies Frisking
• Employs Standard 15.51 cm² GM Pancake Detector
• Ratemeter, MAX Hold, and Scaler Operang Modes
• Simple Two‐Bution Operation
• Count Rate and Scaler Alarms
• Automatic LCD Backlight Activation

Ludlum Contamination Monitor Model 26